PLANTAS FOTOVOLTAICAS PARA P&D EM PETROLINA

Autores

  • Olga de Castro Vilela Universidade Federal de Pernambuco
  • Marco Antonio Galdino Centro de Pesquisas de Energia Elétrica
  • Elielza Moura S. Barbosa Universidade Federal de Pernambuco
  • Emerson Torres Aguiar Gomes Universidade Federal de Pernambuco
  • Diego Rodrigues de Miranda Universidade Federal de Pernambuco
  • Claudio Moisés Ribeiro Universidade Federal do Espírito Santo
  • Adeon Cecilio Pinto Universidade Federal do Vale do São Francisco
  • Eubis Pereira Machado Universidade Federal do Vale do São Francisco
  • Jadsonlee da Silva Sá Universidade Federal do Vale do São Francisco
  • Ricardo Menezes Prates Universidade Federal do Vale do São Francisco
  • Rodrigo Pereira Ramos Universidade Federal do Vale do São Francisco
  • Wedson Pereira da Silva Universidade Federal do Vale do São Francisco
  • Marcia da Rocha Ramos Centro de Pesquisas de Energia Elétrica
  • Kenia Carvalho Mendes Universidade de Pernambuco
  • Victor Mendonça de Azevêdo Fundação para Inovações Tecnológicas
  • José Bione de Melo Filho Companhia Hidro Elétrica do São Francisco
  • Alex Coutinho Pereira Companhia Hidro Elétrica do São Francisco
  • Alcides Codeceira Neto Companhia Hidro Elétrica do São Francisco
  • Eduardo Boudoux Jatoba Companhia Hidro Elétrica do São Francisco

DOI:

https://doi.org/10.59627/cbens.2022.1155

Palavras-chave:

tecnologias fotovoltaicas, análise de desempenho de sistemas fotovoltaicos, impacto de sujidades

Resumo

No âmbito do Cresp – Centro de Referência em Energia Solar de Petrolina será implantada uma instalação fotovoltaica com potência total de 3 MWp, sendo 2,5 MWp numa instalação convencional de Silício cristalino, já em operação, conjuntamente com 0,5 MWp em diversas tecnologias de módulos FV e diferentes configurações, e que atualmente encontra-se em fase de implantação. Toda esta instalação será utilizada como infraestrutura para P&D+I e nela serão efetuados diversos experimentos, estudos e desenvolvimentos, incluindo a avaliação de desempenho comparativo de tecnologias FV, análise de qualidade de energia, modelagem computacional, análise de impacto de sujidades, análise de perdas por reflexão através de IAM (incidence angle modifier), técnicas de O&M, armazenamento e descarte de materiais, análise termográfica de módulos FV, traçado de curvas IV e modelagem da radiação. Uma descrição das instalações FV em implantação na chamada Planta Tecnológica do Cresp e dos experimentos e pesquisas previstos constituem os objetos do presente artigo.

Downloads

Não há dados estatísticos.

Biografia do Autor

Olga de Castro Vilela, Universidade Federal de Pernambuco

Universidade Federal de Pernambuco, Departamento de Energia Nuclear

Referências

Araújo, D. N., Costa, S. C. S., Dupont, I. M., Carvalho, P. C. M., 2018. Impactos da sujidade e efeitos da limpeza no desempenho de módulos fotovoltaicos. In: VII Congresso Brasileiro de Energia Solar-CBENS, Gramado-RS.

Buerhop, CL.; Schlegel, D.; Niess, M.; Vodermayer, C.; Weißmann, R.; Brabec, C. J. (2012). Reliability of IR-Imaging of PV-Plants under Operating Conditions. Solar Energy Materials and Solar Cells, v. 107, p. 154–64.

Caron, J. R., Littmann, B., 2013. Direct Monitoring of Energy Lost Due to Soiling on First Solar Modules in California. IEEE Journal of Photovoltaics. v. 3, n. 1, 2013, p. 336-340.

Chesf, 2019. Folder Institucional do CRESP-Centro de Referência de Energia Solar de Petrolina. Chesf - Companhia Hidro Elétrica do São Francisco. Recife-PE.

Darwish, Z. A., Kazem, H. A., Sopian, K., Al-Goul, M. A., Alawadhi, H., 2015. Effect of dust pollutant type on photovoltaic performance. Renewable and Sustainable Energy Reviews, Elsevier, v. 41, p. 735-744.

EPE-Empresa de Pesquisa Energética,2020. Expansão da Geração – Projetos Fotovoltaicos nos Leilões de Energia - Análises dos leilões A-4 e A-6 de 2019. Nota Técnica No. EPE-DEE-003/2020-r0. 23 de janeiro de 2020.

Fathi, M., Abderrezek, M., 2017. Dust sensor based on luminescent glazing for control of photovoltaic panels cleaning. Clean Tech Environ Policy. v. 19, 2017, p. 1809-1814.

Fanni, L., Virtuani, A., & Chianese, D., 2011. A detailed analysis of gains and losses of a fully-integrated flat roof amorphous silicon photovoltaic plant. Solar Energy, 85(9), 2360-2373.

Fraga, M. M., Campos, B. L. O., Almeida, T. B., Fonseca, J. M. F., Lins, V. F. C., 2018. Analysis of the soiling effect on the performance of photovoltaic modules on a soccer stadium in Minas Gerais, Brazil. Solar Energy, v. 163, n. February, p. 387–397, 2018.

Gholami, A., Khazaee, I., Eslami, S., Zandi, M., Akrami, E., 2018. Experimental investigation of dust deposition effects on photo-voltaic output performance. Solar Energy. v. 159, 2018, p. 346-352.

Guan, Y., Zhang, H., Xiao, B., Zhou, Z., Yan, X., 2017. In-situ investigation of the effect of dust deposition on the performance of polycrystalline silicon photovoltaic modules. Renewable Energy. v. 101, 2017, p. 1273-1284.

Gueymard, C. A., & Ruiz-Arias, J. A., 2016. Extensive worldwide validation and climate sensitivity analysis of direct irradiance predictions from 1-min global irradiance. Solar Energy, 128, 1-30.

Heinrich, M., Meunier, S., Samé, A., Quéval, L., Darga, A., Oukhellou, L., Multon, B., 2020. Detection of cleaning interventions on photovoltaic modules with machine learning. Applied Energy, Elsevier, Vol. 263, p. 114642.

Kaldellis J. K., Fragos, P., 2011. Ash deposition impact on energy performance of photovoltaic generators, Journal of Cleaner Production, v. 19, p. 311-317, 2011.

Kaldellis, J. K., Kokala, A., 2010. Quantifying the decrease of the photovoltaic panels’ energy yield due to phenomena of natural air pollution disposal, Energy, v. 35, p.4862-4869, 2010.

King, B. H., & Robinson, C. D. (2018). Comparative Angle of Incidence Characterization of Utility Grade Photovoltaic Modules (No. SAND-2018-12462). Sandia National Lab.(SNL-NM), Albuquerque, NM (United States).

King, D. L., Kratochvil, J. A., & Boyson, W. E., 2004. Photovoltaic array performance model (pp. 1-43). United States Department of Energy.

Lu, Z. H., & Yao, Q. (2007). Energy analysis of silicon solar cell modules based on an optical model for arbitrary layers. Solar Energy, 81(5), 636-647.

Maghami, M. R., Hizam, H., Gomes, C., Radzi, M. A., Rezadad, M. I., Hajighorbani, S., 2016. Power loss due to soiling on solar panel: A review. Renewable and Sustainable Energy Reviews, Elsevier, v. 59, p. 1307-1316.

Martin, N., & Ruiz, J. M., 2002. A new model for PV modules angular losses under field conditions. International Journal of Solar Energy, 22(1), 19-31.

Oliveira, A. K. V.; Aghaei, M.; Rüther, R., 2020. Detecção Automática de Falhas de Sistemas Fotovoltaicos por Redes Neurais Convolucionais utilizando a Termografia Aérea Infravermelha. VIII Congresso Brasileiro de Energia Solar – Fortaleza.

Pereira, E. B., Martins, F. R., Costa, R. S., Gonçalves, A. R., Lima, F. J. L., Abreu, S. L., Ruther, R.Tiepolo, G. M., Vitorino, S. P. & Souza. J. P., 2017. Atlas Brasileiro de Energia Solar. 2ª. Ed. São José dos Campos. INPE - Instituto Nacional de Pesquisas Espaciais, 2017, v.1. p. 88.

Polo, J., Fernández-Peruchena, C., Salamalikis, V., Mazorra-Aguiar, L., Turpin, M., Martín-Pomares, L., Kazantzidis, A., Blanc, P. & Remund, J., 2020. Benchmarking on improvement and site-adaptation techniques for modeled solar radiation datasets. Solar Energy, 201, 469-479.

Tarpley, J. D., 1979. Estimating Incident Solar Radiation at the Surface from Geostationary Satellite Data. Journal of Applied Meteorology, v. 18, n. 9, p. 1172-1181.

Vilela, O.C., Melo-Filho, J.B, Barbosa, E.M.S., Secundes U.U., Galdino, M.A., Fraidenraich N., 2014. Planta Fotovoltaica de 3 MWp de Petrolina Aspectos Tecnológicos, Legais E Ambientais. V CBENS - Congresso Brasileiro de Energia Solar. Recife-PE. 31 a 03 de abril de 2014.

Yang, D. (2016). Solar radiation on inclined surfaces: Corrections and benchmarks. Solar Energy, 136, 288-302.

Downloads

Publicado

2022-08-16

Edição

Seção

Anais