IMPACTS OF SOLAR TRACKER MISALIGNMENTS ON HIGH CONCENTRATING SYSTEMS

CASE STUDY FOR HCPV SYSTEM DEN-FAE-UFPE

Authors

  • Antônio Carlos Fernandes de Negreiros Universidade Federal de Pernambuco
  • Francisco José Buelvas Uribe Universidade Federal de Pernambuco
  • Douglas Ramos Velozo Universidade Federal de Pernambuco
  • Olga de Castro Vilela Universidade Federal de Pernambuco
  • Elielza Moura de Souza Barbosa Universidade Federal de Pernambuco
  • Naum Fraidenraich Universidade Federal de Pernambuco

DOI:

https://doi.org/10.59627/cbens.2016.2048

Keywords:

HCPV systems, solar tracking, alignment evaluation

Abstract

The paper presents the analysis of the impact of power generation caused by misalignment between the physical structure of the tracker and the sun's rays. It was used as an object of study the Photovoltaic system of high concentration ( HCPV - High Concentrator Photovoltaics) installed by the Group for Alternative Energy Sources (FAE) in the Department of Nuclear Energy (DEN) at the Federal University of Pernambuco (UFPE). Through the measurements it was possible to quantify the decay of power generation in the system output due to the increase in deviation angle between the normal vector to the generator of the plan and the sun's rays. This document presents the main features of HCPV system used, the implemented methodology and a description of a pointing sensor that was developed the experiment.

Downloads

Author Biographies

Antônio Carlos Fernandes de Negreiros , Universidade Federal de Pernambuco

Departamento de Energia Nuclear Grupo de Fontes Alternativas de Energia

Francisco José Buelvas Uribe , Universidade Federal de Pernambuco

Departamento de Energia Nuclear, Grupo de Fontes Alternativas de Energia

Douglas Ramos Velozo , Universidade Federal de Pernambuco

Departamento de Energia Nuclear, Grupo de Fontes Alternativas de Energia

Olga de Castro Vilela , Universidade Federal de Pernambuco

Departamento de Energia Nuclear, Grupo de Fontes Alternativas de Energia

Elielza Moura de Souza Barbosa , Universidade Federal de Pernambuco

Departamento de Energia Nuclear, Grupo de Fontes Alternativas de Energia

Naum Fraidenraich , Universidade Federal de Pernambuco

Departamento de Energia Nuclear, Grupo de Fontes Alternativas de Energia

References

García-Domingo, B.; Aguilera, J.; de la Casa, M. F., 2014. Modelling the influence of atmospheric conditions on the outdoor real performance of a CPV (Concentrated Photovoltaic) module. Energy, 70. pp.239–250.

Gombert, A.; Heile, I.; Wullner, J.; Gertsmaier, T.; van Riesen S.; Gertser, E.; Rottger, M.; 2010. Recent progress in concentrator photovoltaics. Photonics for Solar ENergy Systems III. pp. 772508–772508–9.

Hontoria, L.; Pérez-Higueras, P.; Terrados, J.; Almonacid, G.; 2012. A Real Alternative for Producing Solar Electricity: The CPV. Current State of CPV: A Review.

Luque, A. & Andreev, V., 2007. Concentrator Photovoltaics A. L. Luque & A. Viacheslav, eds., Berlin, Heidelberg: Springer Berlin Heidelberg.

Luque, A.; Hegedus, S. 2011. Handbook of Photovoltaic Science and Engineering. 2nd ed. West Sussex, England: John Wiley & Sons, Ltd.

Luque, I., 2010. Control de seguimiento solar de alta precisión con autocalibración. Universidad Politécnica de Madrid, pp.1–305.

Negreiros, A. C. F. 2013. Desenvolvimento de um sistema de controle em malha fechada para um rastreador solar de alta precisão. Dissertação (Mestrado) – Universidade Federal de Pernambuco. CTG. Programa de Pós-Graduação em Tecnologia Energéticas e Nucleares (PROTEN).

O’Gallagher, J.J., 2008. Nonimaging optics in solar energy. Synthesis Lectures on Energy and the Environment: Technology, Science, and Society, 2(1), pp.1–120.

Pedrosa Filho, M.H.O., Vilela, O.C.; Fraidenraich, N.; 2010. Avaliação da influência dos desvios óticos e de rastreamento na concentração de coletor parabólico linear. Avances en Energías Renovables y Medio Ambiente - ASADES, 14, pp.101–108.

Soitec, 2015. Four-junction solar cell developped using Soitec's expertise in semiconductor materials sets new efficiency record of 38.9% for CPV module. Disponivel em: < http://www.soitec.com/en/news/press-releases/article-1737>. Acesso em: 31 Julho 2015.

Uribe, F. J. B. ; Veloso, D. ; Vilela, O. C. ; Bottler, B. H. ; Barbosa, E. M. DE S. ; Fradenraich, N. 2014. Primeiras Experiências Práticas e Desafios Técnicos de um Sistema Fotovoltaico de Alta Concentração. In: V Congresso Brasileiro de Energia Solar, Recife. Anais do V Congresso de Energia Solar. Recife: ABENS, 2014.

Uribe, F. J. B. ; Vilela, O. C. ; Velozo, D. R.; Negreiros, A. C.; Barbosa, E. M. DE S. ; Fradenraich, N.; 2015. Resultados do Desempenho e Análise Operacional de um Sistema Fotovoltaico de 10 kWp de Alta Concentração Interligado à Rede: Primeiro Ano De Operação. In: XXXVIII Reunión de Trabajo de la Asociación Argentina de Energías Renovables y Medio Ambiente: ASADES.

Published

2016-12-13

How to Cite

Negreiros , A. C. F. de, Uribe , F. J. B., Velozo , D. R., Vilela , O. de C., Barbosa , E. M. de S., & Fraidenraich , N. (2016). IMPACTS OF SOLAR TRACKER MISALIGNMENTS ON HIGH CONCENTRATING SYSTEMS: CASE STUDY FOR HCPV SYSTEM DEN-FAE-UFPE. Anais Congresso Brasileiro De Energia Solar - CBENS, 1–8. https://doi.org/10.59627/cbens.2016.2048

Issue

Section

Anais